Liquid Penetrant Examination

Customer Customer Order No
Customer reference- Test site-

Object

Drawing no- Manufacturing no-
Base material- Filler material-
Welding method- Joint☐ BW Butt Welds (Stumfog) ☐ FW Fillet Welds (kälfog) ☐ Butt Welds & Fillet Welds ☐ -
Heat treatedNo

Examination

Extent☐ 100% ☐ 10% ☐ Spot check ☐ According to instructions MethodColour contrast penetrant
Examination acc. to☐ ISO 3452-1:2013 ☐ EN ISO 3452-1 Acceptance acc. to☐ ISO 23277:2015-2X ☐ EN ISO 23277 ☐ ASME VIII div. 1 app. 8.
Specification no- Surface condition☐ Pickled ☐ Cleaned ☐ Uncleaned

Penetrant system

Cleaner (charge)- Penetrant (charge)MR68NF
Remover charge no- Developer (charge)MR 70
Pre examinationDrying method: Air dry. Drying time: 5 min.
Application of penetrantApplication method: Brush. Penetration time: 20 min. Temp: 20 °C.
RemovingPenetrant removed with: Solvent. Drying method: Air dry. Drying time: 5 min.
DevelopmentMethod: Spray. Temp: 19 °C.

Result

Brightness during the inspection was measured with a lux meter, Testo 540, acc. to EN ISO 3452-1 to an illuminance of .

Signatures

Performed by
Söderhamn, __________________
UNSIGNED
 
Approved by — EN ISO 9712 Level 2 PT
Söderhamn, __________________
UNSIGNED