Penetrant Protocol — ifyllnadsformulär

Penetrant Protocol

CustomerCustomer order no
Customer referenceProject number
Test site
Object
Drawing noBase material
Filler materialManufacturing no
Welding method
Joint type
Heat treatedSketch no
Examination
Extent
Supplementary data
Examination acc to
Acceptance acc to
Specification no
Surface condition
MethodColour contrast penetrant
Penetrant system
CleanerCleaner charge no
PenetrantMR68NF
Penetrant charge noPenetrant remover charge no
DeveloperMR 70
Developer charge no
Standard procedure
Pre examinationDrying method: Air dry. Drying time: 5 min.
Application of penetrantApplication method: Brush. Penetration time: 20 min. Temp: 20 °C.
RemovingPenetrant removed with: Solvent. Drying method: Air dry. Drying time: 5 min.
DevelopmentMethod: Spray. Temp: 19 °C.
Result
According to requirementsSketch note
BrightnessBrightness during the inspection was measured with a lux meter, Testo 540, acc. to EN ISO 3452-1 to an illuminance of
Illuminance
Operator level2

Signatures

Performed by
Söderhamn,
Signerare:
 
Approved by
Söderhamn,
Signerare: